Abstract: This paper investigates the driving scheme of refrigeration compressor and the heat source scheme of reboiler in sulfuric acid alkylation unit. The results show that the reboiler uses heat conducting oil as heat source. The refinery has excessive low pressure steam in summer, the excessive 1.0 MPa steam is used as the heat source of reboiler, and the insufficient heat is provided by the heat conducting oil system. In winter, there is no surplus low pressure steam in the refinery, so all the heat required by the reboiler is provided by the heat conducting oil system. The refrigeration compressor is driven by motor (with gear box). This design scheme can reduce the energy consumption of alkylation unit and optimize the steam pipe network system and power balance of the refinery
Key words: alkylation, refrigeration compressor, reboiler, Utility optimization
Xu Biao, Jin Lei, Duan Fei, Wang Lianglong. Optimization of Design Scheme for Low Temperature Sulfuric Acid Alkylation Unit[J].Petrochemical Design, 2019, 36(4): 24-27.
0 / / Recommend
Add to citation manager EndNote|Reference Manager|ProCite|BibTeX|RefWorks
URL: http://syhgsj.sei.com.cn/EN/10.3969 /j.issn.1005-8168.2019.04.007
http://syhgsj.sei.com.cn/EN/Y2019/V36/I4/24
Design of Deisobutanizer Reboiler in Alkylation Unit
Piping Design of Acidic Medium Pipeline in Sulfuric Acid Alkylation Unit and Its Supporting Units
Cause Analysis of Short Operating Cycle of Reboiler in Debutanizer and the Countermeasures
Research on Schemes for Producing National VI/Beijing VI Gasoline via Non-alkylation Route
Simulation and Optimization of Propylene Refrigeration System
Factors Influencing the Fouling of Reboiler in Deethanizer and the Countermeasures
Cited